Permit: T07PL01738

Parcel: 135050820


Addresses:

6309 E CALLE MARTE

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/16/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
10/11/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL MAKE VENT CONNECTION PROPERLY AT WATER HEATER DRAFT HOOD & FURNACE CONNECTION
2. SHALL PROVIDE BONDING OF BUILDING GAS PIPING
3. SHALL PROVIDE COMBUSTION AIR OPENING FOR
120,000 BTU DEMAND OF DEVICES UPPER SUPPLY FROM BUILDING EXTERIOR SHALL EQUAL MINIMUM 60 SQ. INCHES
4. SHALL SECURE GAS PIPING AT FURNACE SHUT OFF VALVE
5. SEAL T&P PENETRATION INTO BUILDING