Permit: T07PL01704

Parcel: 116172820

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/19/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
10/30/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PROVIDE PERM CAPS ON OLD DRAINAGE INTO GREASE TRAP AT 3-COMP SINK LOCATION
2. PROVIDE APPROVED COUPLING FOR 3-COMP SINK DRAINAGE
3. PERM CAP 3" OLD OUTLET FROM GREASE TRAP
4. PROVIDE 1" AIR GAP FOR SANITIZE DRAIN AT FLOOR SINK FOR 3-COMP SINK
5. PROVIDE TRAFFIC RATED CLEANOUT COVERS AT EXTERIOR CLEANOUTS
6. PROVIDE ROOF FLASHING FOR INTERCEPTOR VENT MADE WEATHER TIGHT
7. SUPPORT & SECURE VENT PIPE
WE VERIFIED STOOL IS NOT ON INTERCEPTOR DRAINAGE
10/24/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*