Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD AT METER SW GAS 889-1888 |
|
| 10/02/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PETITION OF APPEAL #370-07 ON SITE 1. DRYER VENT SHALL BE SMOOTH INTERIOR SURFACE THROUGH ROOF, USE POP RIVETS FOR CONNECTION NO SCREWS TO OBSTRUCT LINT WITH WEATHER 90 DEG. TERMINATION OR T-TOP SIZING SHALL BE 4" 2. T&P TO BE 1" ABOVE LIP OF DRAIN PAN 3. WATER HEATER VENT TO BE MADE UP CORRECTLY WITH 3-GALV SCREWS AT EACH JOINT 4. PROVIDE BONDING OF BUILDING GAS PIPING 5. PROVIDE MINIMUM 100 SQ. INCHES UPPER & LOWER COMBUSTION AIR IF INFILTRATION METHOD IS USED. 6. PROVIDE VACUUM BREAKER AT NEW HOSE BIB. |