Permit: T07PL01639

Parcel: 125160300

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/05/2007 PLUMBING - FINAL Approved CORRECTIONS MADE OK
OK FOR GAS
UCC LEFT AT METER
SW GAS 889-1888
11/01/2007 PLUMBING - FINAL Cancelled IVRS - RI canceled
10/24/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PRESSURE TEST OK
2. OK TO COVER UNDERGROUND
3. MAKE ALL CONNECTIONS -- HOOK UP ALL APPLIANCES
4. CAPPED TEES WITH NO CONNECTIVE APPLIANCE TO BE REMOVED AND USE APPROVED 90 DEG. ELL
5. 1/2" ANCILLARY PIPING TO FIREPLACE MAY NOT BE MADE BY THE USE OF A FLEX CONNECTOR
6. FURNACE REQUIRES A SEDIMENT TRAP