Permit: T07PL01516

Parcel: 104071440


Addresses:

1507 W GARDNER ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/12/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
CORRECTIONS MADE OK
OK FOR GAS
UCC LEFT AT METER
OK TO COVER
SW GAS 889-1888
09/04/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PIPE T&P TO EXTERIOR
DRAIN NOT CAPABLE OF T&P DISCHARGE. ALSO AG REQUIRED
- SECURE DRAFT COLLAR TO WH
- REMOVE TAPE AT B-VENT
- INSTALL B-VENT IN CORRECT DIRECTION OF FLOW
- TOOL MARKS VISIBLE ON BELOW GRADE SCOTCH KOTE
- PLUMB RISER AT METER
- PROVIDE SOME CLEARANCE AROUND UNION AT HOUSE
- SECURE PIPE SUPPORTS