Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/11/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 12:05 PM NO ANSWER CONTINUED NOT READY INSPECTION RESULTS WILL RESULT IN REINSPECTION FEES |
|
| 08/30/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SHALL PROVIDE FUNCTIONAL APPROVED VENT CAP FOR FURNACE VENT |
|
| 08/29/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE VENT & CAP FROM ITEM #5 OF 8/24/07 INSPECTION 791-7800 GREG |
|
| 08/24/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SHALL PROVIDE 1" MINIMUM CLEARANCE FOR DOUBLE WALL VENT AND COMBUSTIBLE MATERIAL AT ROOF LINE FOR WATER HEATER, AND SECURE THIS VENT WITH 3-GALV SCREWS AT EACH JOINT. REMOVE TAPE FOR PROPER INSPECTION OF VENT JOINTS. 2. PROVIDE NIPPLE WITH NO THREADS ON DISCHARGE END OF TEMPERATURE & PRESSURE RELIEF DRAIN 90 DEG. ON EXTERIOR. 3. SECURE GAS PIPING AT DROP AT FURNACE CLOSET TO LIMIT ALL MOVEMENT 4. PLUG OR CAP OLD GAS PIPING IN HOUSE 5. VENT FROM FURNACE TO BE EXTENDED TO 3' ABOVE TOP OF COOLER INTAKE WITH DOUBLE WALL VENT PIPING AND A FUNCTIONAL APPROVED VENT CAP. |