Permit: T07PL01490

Parcel: 133310380


Addresses:

9050 E MERRIMAC PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/13/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
09/11/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
12:05 PM NO ANSWER
CONTINUED NOT READY INSPECTION RESULTS WILL RESULT IN REINSPECTION FEES
08/30/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SHALL PROVIDE FUNCTIONAL APPROVED VENT CAP FOR FURNACE VENT
08/29/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PROVIDE VENT & CAP FROM ITEM #5 OF 8/24/07 INSPECTION

791-7800 GREG
08/24/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE 1" MINIMUM CLEARANCE FOR DOUBLE WALL VENT AND COMBUSTIBLE MATERIAL AT ROOF LINE FOR WATER HEATER, AND SECURE THIS VENT WITH 3-GALV SCREWS AT EACH JOINT. REMOVE TAPE FOR PROPER INSPECTION OF VENT JOINTS.
2. PROVIDE NIPPLE WITH NO THREADS ON DISCHARGE END OF TEMPERATURE & PRESSURE RELIEF DRAIN 90 DEG. ON EXTERIOR.
3. SECURE GAS PIPING AT DROP AT FURNACE CLOSET TO LIMIT ALL MOVEMENT
4. PLUG OR CAP OLD GAS PIPING IN HOUSE
5. VENT FROM FURNACE TO BE EXTENDED TO 3' ABOVE TOP OF COOLER INTAKE WITH DOUBLE WALL VENT PIPING AND A FUNCTIONAL APPROVED VENT CAP.