Permit: T07PL01482

Parcel: 117081220


Addresses:

838 S RUBIO AV

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Date Description Inspector Results Comments
09/10/2007 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
08/23/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE MINIMUM 10' OF METALLIC WATER PIPING IN GROUND FOR BUILDING
2. ALL PIPING REQUIRED TO HAVE MINIMUM 12" COVER
3. PROVIDE BLUE TRACER WIRE FROM METER TO BUILDING ENTRY CONNECTED TO YARD PIPING AT 8' INTERVALS
4. HOSE BIBS SHALL HAVE VACUUM BREAKERS
5. CLAMP CONNECTION FOR GROUNDING WIRE TO BE FREE OF PAINT ON PIPING FOR GOOD CONNECTION AT COPPER PIPE OF WATER SERVICE.