Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
Permit Number - T07PL01460
Inspection Description - PLUMBING - FINAL
Inspection Status - Not ready for Inspection
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/07/2007 | PLUMBING - FINAL | Not ready for Inspection | 1. GAS REPIPE - TAPE MARRED PIPE, WHERE PROTECTIVE COATING HAS BEEN STRIPPED OFF 2. CAP OFF OR REMOVE OLD PIPING 3. FLEX CONNECTOR MAY NOT PASS THRU WALL OF APPLIANCE, HARD PIPE TO OUTSIDE FURNACE AND THEN ATTACH FLEX 4. REQUIRE 3 SHEETMETAL SCREWS AND EACH JOINT OF VENT CONNECTOR AT WATER HEATER 5. LEFT GAS CARD SW GAS 889-1888 |