Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* OWNER WILL MOVE BONDING TO WATER HEATER AREA |
|
| 08/22/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* MAKE CORRECTION LISTED BELOW CALL IN 03050 & 03090 FOR GAS CLEARANCE 1. SHALL PROVIDE 1" MINIMUM CLEARANCE FROM DOUBLE WALL VENT PIPE AT WATER HEATER & COMBUSTIBLE WOOD AT PENETRATIONS THRU ROOFS. SHALL PROVIDE ROOF FLASHING ON VENT PENETRATION ON ROOF TO BE WEATHER TIGHT OF NON-COMBUSTIBLE MATERIAL. 2. SHALL PROVIDE BONDING OF BUILDING GAS PIPING 3. VENT FROM FURNACE TO BE EXTENDED UP 3' ABOVE TOP OF COOLER INTAKE WITH DOUBLE WALL VENT PIPING (FULL SIZE) WITH APPROVED VENT CAP WHEN WITHIN 10' OF COOLER INTAKE |