Permit: T07PL01426

Parcel: 135110360


Addresses:

7535 E MARC PL

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/30/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE CITY SIGNED PETITION OF APPEAL FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF ON SITE.
2. PROVIDE CORRECT 125# PRESSURE RELIEF WITH NO THREADS ON DISCHARGE END OF NIPPLE.
3. DOUBLE WALL VENT TO BE 3' ABOVE TOP OF COMBUSTION AIR INTAKE WITH APPROVED VENT CAP