Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07PL01397
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/08/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
01/09/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) YOU ARE REQUIRED TO HAVE A LICENSED PLUMBING CONTRACTOR DOING THIS WORK. PLUMBER WAS TO BE ON SITE FOR INSPECTION 2) CONTRACTOR TO PAY REINSPECTION FEE |
|
11/29/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. EXTENSIVE REMODELING HAS BEEN COMPLETED WITHOUT INSPECTIONS 2. ALL NEW WORK INDICATED ON THE APPROVED PLAN TO BE INSPECTED. ALL NEW WORK COVERED W/O INSPECTION TO BE OPENED FOR INSPECTOR APPROVAL 3. ALL CHANGES TO THE PLAN TO BE REDLINED BEFORE INSPECTION 4. GAS PRESSURE GAUGES TO BE 15LB. WITH 1/10 POUND INCREMENTATION 5. REMOVE DEMO'D GAS PIPING 6. PLUMBERS TAPE NOT APPROVED STRAP - FURNCO NOT PERMITTED FOR PLASTIC - N/H BAND NOT PERMITTED FOR PLASTIC - CLEANOUTS MAY NOT BE DIRECTLY EMBEDDED IN SIDEWALK - REQUIRE TEST ON ALL NEW PIPING - REQUIRE 2X THE PIPE DIAMETER BETWEEN TRAP WEIR AND POINT OF VENT HAVE PLUMBER ON SITE AT TIME OF NEXT INSPECTION * MAY NOT BE A COMPLETE LIST |