Permit: T07PL01393

Parcel: 130152670


Addresses:

4601 E 27TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/12/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
09/10/2007 PLUMBING - FINAL Not ready for Inspection NOBODY HOME
08/07/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
WATER HEATER FLOOR NEEDS TO BE ABLE TO SUPPORT WATER HEATER

1. SHALL PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER AND FURNACE
2. SUPPORT GAS PIPING TO WATER HEATER
3. REMOVE TAPE AT DRAFT SPACE AT SINGLE TO DOUBLE WALL VENT CONNECTION PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING
4. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING TO BE APPROVED RIDGID PIPING (NO FLEX) GRAVITY DRAINING TO DAYLIGHT
5. SHALL PROVIDE BONDING OF BUILDING GAS PIPING SYSTEM
6. PROVIDE AGA OR CSA APPROVED GAS VALVE & FLEX FOR STOVE
7. VENTS TO BE DOUBLE WALL THRU CEILING & ROOF TO TERMINATION AT APPROVED VENT CAP MINIMUM 3' ABOVE TOP OF COOLER INTAKE