Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/02/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* GAUGE READING 2.8 PSI FIND AND CORRECT YOUR LEAK THEN CALL FOR INSPECTION |
|
| 09/28/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SECURE PIPE NEAR WH TEST AT 10 PSI, GAGE IS AT 6 AND GAGE BACK IS RUBBING AGAINST NEEDLE |
|
| 09/27/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSTALL FLASHING ON ROOF PENETRATION - RETEST KEEP PIPE FROM TOUCHING ROOF, SUGGEST SWING JOINT AT FURNACE RISER. AGA VALVE IS TO BE INSTALLED UPSTREAM OF FLEX 1" CLEARANCE REQUIRED BETWEEN B VENT AND WOOD |
|
| 09/24/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* GAUGE PAINTED, UNABLE TO READ PROVIDE ACCESS TO ROOF AND ATTIC CORRECTIONS HAVE NOT BEEN MADE YOU MAY BE CHARGED A REINSPECTION FEE IF YOU CONTINUE TO FAIL INSPECTION |
|
| 08/17/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SYSTEM IS LEAKING REMOVE OLD PLUG COCKS RETEST SYSTEM DO NOT DSG GAUGE TEST AT 10 PSI INSTALL FLEX DOWNSTREAM OF AGA LISTED GAS SHUTOFF VALVE SECURE VENT CONNECTOR W/SCREWS INSTALL TYPE B VENT THROUGH ROOF PROVIDE A PERMIT FOR NEW ROOFTOP FURNACE PROVIDE A PLAN FOR USE OF CSST GAS TUBING PROVIDE ACCESS TO ATTIC AND ROOF SUPPORT AND SECURE PIPING IN ATTIC SEDIMENT TRAP REQUIRED AT FURNACE CAP ABANDONED WALL FURNACE VENT PENETRATION |
|
| 08/16/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTEND WATER HEATER TPR VALVE 6" FROM GROUND 2) DRIP LEG WATER HEATER 3) INSTALL APT SHUT OFF STOVE |
|
| 08/14/2007 | PLUMBING - FINAL | Cancelled |