Permit: T07PL01273

Parcel: 116210070


Addresses:

51 S GRANDE AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/26/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
07/25/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. 1" CLEAR AROUND FLUE VENT THRU ROOF FOR WATER HEATER
2. PIPE T&P DOWN TO 6" TO 24" OF GROUND
3. COMPLETE LIST FROM 7/23/07
07/23/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. EXTEND FLUE VENT 3' ABOVE COOLER THAT ARE WITHIN 10'
2. PROVIDE NEW FLEXES AT WALL UNITS AND AGA APPROVED VALVES
3. ADD SUPPORT ON GAS PIPING ON WEST WALL