Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T07PL01272
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2007 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
|
| 10/05/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* 1. I'M GOING TO INSIST THAT ALL UNDERGROUND PIPING HAVE AT LEAST 12" OF COVER AT ALL POINTS 2. WIRE NUTS ARE TO WATERPROOF TYPE |
|
| 09/12/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* 1. PIPING UNDER DRIVE IS COVERED WITH LESS THAN 18" OF FILL 2. 12" OF COVER IS REQUIRED ELSEWHERE REMOVE DEBRIS AND GARBAGE FROM TRENCH EXPOSE ALL COVERED PIPE 3. LETTERING IS TO FACE UP 4. TRANSITION FITTINGS COVERED 5. BLUE TRACER WIRE IS REQUIRED |
|
| 08/15/2007 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PIPING UNDER DRIVE SHALL BE 18" DEEP - 12" REQUIRED IN OTHER AREAS - INSTALL W/PIPE MARKINGS FACING - FE PVC FITTINGS NOT ALLOWED AT METALLIC CONNECTIONS - USE PROPER ALIGNMENT AT ALL JOINTS - TRACER WIRE REQUIRED - USE BLUE, ATTACH AT 8' OC |