Permit: T07PL01267


Addresses:

1080 N COLUMBUS BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/22/2007 PLUMBING - INTERMEDIATE Approved
07/31/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- YOU ARE INSTRUCTED TO STOP WORK AND REVISE PERMIT
- YOU ARE INSTALLING ABOVE FLOOR PIPING, WH REPLACEMENT, ELECTRICAL, STRUCTURAL AND MECHANICAL.
- STEVE W/WIND RIVER CONSTRUCTION
STOP WORK AND DO NOT COVER ANYTHING WITHIN STORE
- SEWER REPLACEMENT OUTSIDE OK TO COVER
- FOR DRAIN REPLACEMENT & INTERMEDIATE PLUMBING;
ALL FIXTURES REQUIRE VENTS. LAV TRAP ARM 1 1/2" MAX.
ISLAND SINK VENT REQUIRES WYE PATTERN FITTING & C.O
07/27/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1/4" PER FOOT SLOPE REQUIRED ON 3" DRAIN
REMOVE SUN BURNED FITTINGS
WATER TEST
MISSION COUPLINGS REQUIRED
SEPARATE WASH & RINSE FROM SANITIZE COMPARTMENTS FOR FINAL