Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/30/2007 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 10/25/2007 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* TEST TO HOLD WITH NO PRESSURE LOSS |
|
| 10/19/2007 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1. SHALL PROVIDE APPROVED GAS SHUT OFF VALVE (AGA OR CSA) AT SERVICE 2. SHALL PROVIDE BONDING OF BUILDING GAS PIPING 3. PROVIDE COMBUSTION AIR FOR WATER HEATER 4. SHALL PROVIDE SELF-CLOSING AIR SEALED DOOR FOR FURNACE IN BEDROOM AND SEPARATION OF RETURN AIR INTAKE FROM COMBUSTION AREA OF FURNACE. 5. VENT FROM FURNACE TO BE MADE UP OF CORRECTLY WITH 3-GALV SCREWS AT EACH JOINT. 6. WATER HEATER TEMPERATURE & PRESSURE RELIEF TO BE MADE UP, GRAVITY DRAIN TO DAYLIGHT. RETEST SYSTEM - YARD PIPING OK 7. APPLIANCE SHUT OFF VALVES TO BE ACCESSIBLE FLEXES SHALL NOT PENETRATE SHEETROCK |
|
| 10/15/2007 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* TEST W/15 PSI GUAGE W/10 PSI INCREMENTATIONS SUPPORT PIPING AT METER PIPING IS NOT DEEP ENOUGH ROCKS TOUCHING PIPING TOOL MARKS ARE VISIBLE INSIDE HALL NOT YET INSPECTED |
|
| 10/05/2007 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 2:30 INSP. REQUESTED. NO ONE HOME. YARD PIPING REQUIRES 12" OF COVER. PIPING SHALL BE CONTINUOUSLY SUPPORTED W/CLEAN FILL PIPING CANNOT BE UNDER STRAIN PRIME, THEN WRAP ALL TOOL MARKS, SCRAPES, ETC. HOUSE SERVICE SHUT OFF VALVE REQUIRED AT HOUSE ACCESS TO ALL GAS APPLIANCES REQUIRED. |
|
| 07/23/2007 | PLUMBING - GAS PRESSURE TEST | Cancelled | CANCELLED PER OWNER ERIC VANCE #733-6936 |