Permit: T07PL01177

Parcel: 127121270


Addresses:

5720 E 5TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/01/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
07/23/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. USE LISTED TRANSITION FITTINGS ON B VENT EXTENSION OR USE LIKE MATERIALS
2. PROVIDE APPROVED VENT CAP ON B VENTS
3. PROVIDE A LISTED VENT TEE AT WH TO FURN CONNECTION
4. SEDIMENT TRAP REQUIRED ON GAS APPLIANCES
5. T&P MUST TERMINATE WITHOUT THREADS ABOVE GRADE OR PROVIDE PETITION OF APPEAL TO TERMINATE T&P INTO PAN AND INSTALL 125 PSI EXTERIOR RELIEF VALVE.
07/20/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CANCELLED
07/18/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. EXTEND FLUE VENT 3' ABOVE COOLER
2. PROVIDE AGA APPROVED VALVES AND FLEXES STOVE, WATER HEATER AND FURNACE.
3. PIPE T&P FOR WATER HEATER TO DAYLIGHT
4. ADD SUPPORT GAS PIPING ABOVE GROUND
5. PRESSURE TEST OK