Permit: T07PL01165

Parcel: 131091540


Addresses:

5707 E 29TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/01/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
07/24/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE UPPER & LOWER COMBUSTION AIR FROM INFILTRATION EQUAL TO 100 SQ. INCHES EACH OR OUTSIDE SOURCE OF COMBUSTION AIR EQUAL TO 40,000 BTU DEVICE.
2. SHALL PROVIDE DIELECTRIC CONNECTION FOR COPPER TO GALVANIZED PIPING ON HOT SIDE.
3. SHALL PROVIDE NEW AGA OR CSA APPROVED
GAS VALVE & FLEX
4. WATER HEATER TEMPERATURES & PRESSURE RELIFE DRAIN SHALL GRAVITY DRAIN TO DAYLIGHT TERMINATING AT 90 DEG. DOWN 6"-24" FROM FINISH GRADE.