Permit: T07PL01157

Parcel: 112033290


Addresses:

3250 N ANDERSON DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/11/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
07/09/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CONNECT DRAFT COLLAR TO WH AND SECURE
2. GAS PIPING PENETRATING ROOF REQUIRES MECHANICAL FLASHING. SEE PREVIOUS NOTES.
07/03/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRECT VENT PIPING - REMOVE 3X5 TEE AND USE PROPER TRANSITION OR INSTALL 3" B VENT TO TERMINATION

CORRECT UPPER COMBUSTION AIR OPENING
FLASH GAS PIPING OR ROUTE UNDER AIR OPENING