Permit: T07PL01123

Parcel: 134211780


Addresses:

7043 E KENYON DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/23/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
07/20/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PIPING HAS BEEN COVERED WITHOUT APPROVAL IN YARD
CONTRACTOR TO PAY REFEE PRIOR TO FINAL INSPECTION
SEE NOTE #6 THIS SHEET, EXPOSE PIPING FOR INSPECTION.
07/09/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PETITION OF APPEAL #340-07 ON SITE
COMPLY WITH NOTE #6 FOR BUILDING GROUND OR YOU SHALL BE REFEE'D
07/03/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ALL PIPING TO BE SUPPORTED & SECURED PROPERLY
I.E WATER HEATER LOCATION
2. WATER PIPING AND ALL FLAMMABLES TO BE MINIMUM 1" CLEARANCE FROM DOUBLE VENT & 6" FROM SINGLE WALL VENT.
3. REMOVE MATERIAL FROM WYE VENT FITTING FOR INSPECTION & VERIFY CORRECT VENTING OF WATER HEATER/FURNACE
4. PROVIDE SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER
5. SHALL PROVIDE WATER HAMMER ARRESTORS FOR HOT & COLD SUPPLY TO WASHING MACHINE.
6. SHALL PROVIDE MINIMUM 10' OF METALLIC PIPING FOR BUILDING GROUND AT EXTERIOR YARD LOCATION
7. SHALL PROVIDE NIPPLE ON DISCHARGE END OF 125# PRESSURE RELIEF WITH NO THREADS ON DISCHARGE END
8. SHALL PROVIDE CITY SIGNED PETITION OF APPEAL FOR WATER HEATER INSTALLATION ON SITE.
9. PROVIDE SEPARATION OF HOT & COLD TUBING
10. VENT FROM WATER HEATER FURNACE TO BE 3' ABOVE TOP OF INTAKES WITHIN 10' WITH DOUBLE WALL VENT PIPE AND CAP