Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07PL01095

Parcel: 136212780


Addresses:

2931 S MARVIN AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/25/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
GASTO FURNACE/WATER HEATER ONLY OK
SW GAS 889-1888
06/22/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. GAS PIPING TO FIREPLACE REQUIRES CONTROL VALVE OUTSIDE OF THE HEARTH WITHIN 6' IN THE SAME ROOM AS FIREPLACE.
2. WATER HEATER SHALL HAVE VENT CONNECTED CORRECTLY HAVE 3-GALV SCREWS AT EACH JOINT, REMOVE DUCT TAPE AT SINGLE TO DOUBLE WALL CONNECTION TO KEEP DRAFT SPACE CLEAR.
3. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN TO DAYLIGHT WITH APPROVED PIPING MATERIAL. EXPOSE TERMINATION.
4. PRIMER THEN TAPE ALL TOOL MARKS & FITTINGS BELOW GRADE