Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07PL01028
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/18/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 06/15/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CAN COVER AREAS NOT AFFECTED BY THESE ITEMS 2) ALL HOSE BIBS REQUIRE VACUUM BREAKERS WITH TAMPER SCREW BROKEN OFF 2) WATER HEATER SHALL HAVE 18" IN WALL COPPER PIPING 3) OVERHEAD PIPING TO BE SUPPORTED AT 32" INTERVALS 4) REMOVE OLD TUBING AND PROVIDE 1" MINIMUM CLEARANCE FROM COMBUSTIBLES FOR WATER HEATER FLUE VENT IN ATTIC |