Permit: T07PL01018

Parcel: 127101400


Addresses:

6230 E HAWTHORNE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/16/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
07/12/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
P OF A 341-07
OK TO COVER YARD PIPING
06/12/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PSI TEST REQUIRED USE 15 PSI GAUGE
2. EXTERIOR UNION MUST BE ABOVE GRADE OR REMOVE
3. TRACER WIRE REQUIRED ON PE
4. RIDGID PIPE REQUIRED AT WH, FURNACE
5. FLEX IS FOR APPLIANCE CONNECTIONS ONLY
6. SUPPORT PIPING
7. AGA VALVES REQUIRED - NEW FLEX REQUIRED AT NEW WH
8. PROVIDE PETITION OF APPEAL FOR T&P DRAIN TERMINATION.
9. INSTALL DRAIN PAN AND 125 PSI RELIEF VALVE ON EXTERIOR WATER SUPPLY
10. SECURE VENT CONNECTORS W/SHEET METAL SCREWS
11. REPLACE STOVE PIPE W/GALV VENT PIPE AT FURNACE
12. EXTEND TYPE B VENT TO 3' ABOVE COOLER