Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07PL00981

Parcel: 11306193A


Addresses:

2408 E LIND RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/15/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS MADE
2) OK FOR GAS
3) UCC LEFT AT METER
06/12/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ALL FIXED APPLIANCES REQUIRE SEDIMENT TRAP.
2. VENT CONNECTOR BACKPITCHED.
3. USE APPROVED VENT REDUCER.
4. PROVIDE BOND BETWEEN GAS PIPING AND WATER PIPING.
5. PROVIDE ACCESS TO ATTIC - PROVIDE LADDER TO ROOF
06/08/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ONE HOME UNABLE TO DO INSPECTION 1:50 PM