Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07PL00891
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/31/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
05/30/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MASTER BEDROOM LAV ANGLE STOP TO BE PROPERLY SECURED. 2. MASTER BATH SHOWER VALVE TO HAVE BACKING & BE PROPERLY SUPPORTED. 3. INSULATION AT REAR EXTERIOR HOSE BIB LOCATION TO BE PROPERLY SEALED. FAILURE TO COMPLY WILL RESULT IN REFEE |
|
05/29/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHALL HAVE NEW WATER HEATER ADDED TO PERMIT 2. SHALL PROVIDE 18" MINIMUM COPPER IN WALL AT WATER HEATER LOCATION. 3. SHALL MAKE UP WATER HEATER VENT CORRECTLY WITH 3-GALV SCREWS AT EACH JOINT OF VENT PIPING. 4. SHALL PROVIDE DRIP LEG AT GAS ENTRY TO WATER HEATER. 5. SHALL PROVIDE WATER HAMMER ARRESTORS FOR HOT & COLD SUPPLY TO WASHING MACHINE. 6. SHALL SECURE ALL ANGLE STOPS PROPERLY. 7. PROVIDE SEPARATION OF HOT & COLD TUBING. 8. SHALL INSULATE WATER SUPPLY TO EXTERIOR REAR HOSE BIB TO AVOID FREEZING AND BREAK OFF HOSE BIB TAMPER SCREW. 9. MASTER BATH SHOWER VALVE TO HAVE CORRECT SUPPORT. |