Permit: T07PL00890

Parcel: 105100280


Addresses:

4341 N STANLEY PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/20/2007 PLUMBING - FINAL Approved 1. PROVIDE INSPECTION HISTORY FOR WATER HEATER INSTALLED OK
2. CORRECTIONS MADE OK
3. OK FOR GAS
06/08/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRECT LEAK
FLASHING
SUPPORT
06/01/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. UNIONS TO BE IN AN ACCESSIBLE LOCATION
2. FINISH PIPING AT NEW METER LOCATION
PRIME AND TAPE UNDERGROUND FITTINGS AND MARRED PIPE
3. SUPPORT VERTICAL PIPE ON WALL
4. INSTALL APPROVED ROOF FLASHING AT ROOF PENETRATIONS
5. INSTALL SEDIMENT TRAPS AT WATER HEATER & FURNACE
WATER HEATER INSTALLED W/O PERMIT
NO APPROVED BASE
NO APPROVED T&P RELIEF DRAIN

INSTALL BOND BETWEEN METALLIC WATER PIPING AND GAS (WATER HEATER) -- ALL VALVES TO BE AGA OR CSA APPROVED