Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/20/2007 | PLUMBING - FINAL | Approved | 1. PROVIDE INSPECTION HISTORY FOR WATER HEATER INSTALLED OK 2. CORRECTIONS MADE OK 3. OK FOR GAS |
|
| 06/08/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* CORRECT LEAK FLASHING SUPPORT |
|
| 06/01/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. UNIONS TO BE IN AN ACCESSIBLE LOCATION 2. FINISH PIPING AT NEW METER LOCATION PRIME AND TAPE UNDERGROUND FITTINGS AND MARRED PIPE 3. SUPPORT VERTICAL PIPE ON WALL 4. INSTALL APPROVED ROOF FLASHING AT ROOF PENETRATIONS 5. INSTALL SEDIMENT TRAPS AT WATER HEATER & FURNACE WATER HEATER INSTALLED W/O PERMIT NO APPROVED BASE NO APPROVED T&P RELIEF DRAIN INSTALL BOND BETWEEN METALLIC WATER PIPING AND GAS (WATER HEATER) -- ALL VALVES TO BE AGA OR CSA APPROVED |