Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/05/2007 | PLUMBING - SEWER HCS CONNECT | Approved | ||
| 05/30/2007 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* 1. NOT INSTALLED PER PLAN 2. NO REDLINES ON SITE 3. MAY NOT INTERMINGLE MATERIAL TYPES I.E SCH 40 ABS - SDR 35 PIPING INSTALLED TO BE TYPICAL THROUGHOUT 4. 2-WAY CLEANOUT FITTING ONLY ALLOWED WHERE BUILDING DRAIN IS CONNECTED TO THE BUILDING SEWER. ALL OTHER CLEANOUTS TO BE DIRECTIONAL, IN THE DIRECTION OF FLOW 5. PIPING IS TO BE INSTALLED WITH A UNIFORM SLOPE ON A FIRM BED AND SHADED. 6. PIPING MUST HAVE GREEN TRACER WIRE PER HB 2256 7. I CANNOT APPROVED THE INSPECTION UNTIL ALL PIPE IS INSTALLED AND ALL CONNECTIONS MADE. NOTE: BUILDING SEWER TEST IS NOT TEN FEET -- ONLY TO GROUND LEVEL. AFTER PIPING IS APPROVED, THEN I NEED TO SEE THE TANK PUMPED AND THE BOTTOM BROKEN, HAVE FILL ON SITE. |