Permit: T07PL00859

Parcel: 112063200


Addresses:

2110 E WATER ST #01

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/20/2009 PLUMBING - GAS PRESSURE TEST Approved
03/18/2008 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
1 1/2 STUBBED UP TO 2' FROM SOUTHWEST CORNER OF WALL IN YARD TO 1" STUB UP AT GUEST HOUSE, 1" STUB UP AT NEW WATER HEATER LOCATION AT SOUTHEAST CORNER OF MAIN HOUSE UNDER ROOF STRUCTURE, 3/4" STUB UP AT EXTERIOR SOUTH FOR STOVE, AND 1" STUB UP AT SOUTH END OF EXISTING HEAT PUMP ONLY

RETEST PIPING AT LATER DATE

1. COMPLETE GAS PIPING TO FURNACE LOCATION
2. INSTALL NEW WATER HEATERS CORRECTLY AND HAVE THEM ADDED TO PERMIT ACTIVITY CARD
3. WATER HEATER AT GUEST HOUSE REQUIRES T&P DRAIN PIPING & WEATHERPROOF ENCLOSURE WITH VENT PIPING FREE OF TAPE AT JOINTS WITH 3-GALV SCREWS AT EACH JOINT OF VENT PIPING
PROVIDE WEATHERPROOF ENCLOSURE
4. NOTE: IF YOU INSTALL LARGER THAN 100,000 BTU WATER HEATERS YOUR GAS PIPING COULD BE UNDER SIZED
5. EXISTING GUEST HOUSE WATER HEATER
REQUIRES 1" MINIMUM CLEARANCE FROM DOUBLE WALL AVENT AND COMBUSTIBLES AND CORRECT SUPPORT TO SECURE PROPERLY.
6. PROVIDE APPROVED VENT PIPING FOR FURNACE IN MAIN HOUSE WITH APPROVED VENT CAP PROPERLY SECURED FREE OF TAPE AT JOINTS
7. IF ELECTRICAL IS REQUIRED FOR WATER HEATER, PROVIDE PLAN AND PERMIT WITH INSPECTION HISTORY.

PIPING PER R2 REVISED PLAN 3/17/08 KV
GAS IS CURRENTLY ON AT EXISTING METER LOCATION
03/14/2008 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOT PER PLAN; SIZE
TEST W/15 PSI GAUGE
NEW WH'S REQUIRE PERMITS AND MAY ALSO REQUIRE ELECTRICAL PERMITS.