Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 06/19/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* YOUR TEMPERATURE & PRESSURE RELIEF DRAIN FROM YOUR WATER HEATER TERMINATES BEHIND THE TABLE WITH THE GRANITE PIECE ON TOP AT THE NORTHEAST CORNER OF YOUR HOUSE APP 6" FROM GROUND THIS NEEDS A 90 DEG. DOWN TERMINATION ON IT. |
|
| 05/30/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SHALL PROVIDE RIDGID NIPPLE THRU FURNACE APPLIANCE HOUSING. 2. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN SHALL BE FULL SIZE PIPING GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL ON SITE SIGNED BY CITY WITH CORRECT INSTALL. 3. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO FURNACE AND WATER HEATER. 4. REMOVE TAPE AT SINGLE TO DOUBLE WALL VENT CONNECTION ON WATER HEATER & FURNACE AND PROVIDE 3-GALV SCREWS AT EACH VENT JOINT. 5. EXTEND DOUBLE WALL VENT ON ROOF TO 3' ABOVE AIR INTAKE REINSTALL CAP. PETITION OF APPEAL FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF |