Permit: T07PL00792

Parcel: 106120810


Addresses:

1602 W HIGGINS LN

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/15/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SCOTCH COAT REQUIRES MINIMUM TWELVE INCHES OF COVER.
2. REMOVE APPLIANCE CONNECTOR AND HARDPIPE CONNECTION AT UNIT.
3. TEST ENTIRE SYSTEM - DO NOT TEST THRU APPLIANCES
05/15/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
1. T&P RELIEF DRAIN TO BE APPROVED MATERIAL
BLK. IRON PIPE NOT APPROVED FOR WATER
T&P RELIEF DRAIN TO TERMINATE POINTING DOWN.
2. ALL OTHER CORRECTIONS MADE OK
OK FOR GAS

SW GAS 889-1888
05/09/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. IF THE GAS LINE WAS REPLACED, EXPOSE ALL OF THE GAS LINE FOR INSPECTION
2. REQUIRE SEDIMENT TRAPS AT WATER HEATER AND FURNACE
3. REQUIRE PROPER VENTING FOR FURNACE AND FOR WATER HEATER
4. REQUIRE BOND BETWEEN WATER AND GAS PIPING
UNDERGROUND PIPING TO BE SCOTCH COAT
PIPING MAY NOT BE INSTALLED UNDERGROUND UNDER ANY BLDG.