Permit: T07PL00714

Parcel: 128010310


Addresses:

1104 S WILMOT RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T07PL00714

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/03/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
05/02/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
05/01/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PROVIDE MAX 135 DEG. CHANGE OF DIRECTION AT HAND SINK DRAIN ON HORIZONTAL DRAINAGE.
2. PROVIDE MINIMUM 1/4" PER FOOT FALL ON 3" GREASE TRAP INLET PIPING. PROVIDE VENT DOWNSTREAM OF GREASE TRAP PER PLAN WITH VENT FROM FLOW CONTROL TIED INTO VENT THRU ROOF.
3. PROVIDE GALV CAP AT OLD DRAINAGE BY WATER HEATER
4. PROVIDE FOAM WRAP THRU CONCRETE AT FLOOR LEVEL ON PIPING.
04/24/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*