Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 04/13/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SHALL PRIME THEN TAPE TOOL MARKS AT HORIZONTAL PIPING AT METER RISER PRIOR TO COVERING. 2. SHALL PROVIDE GOOD BOND AT BONDING CLAMP ON PIPE. (REMOVE SCOTCH COATING UNDER CLAMP) 3. PROVIDE SUPPORT AT GAS PIPING AT WATER HEATER. SW GAS 889-1888 |