Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07PL00645

Parcel: 122183240


Addresses:

3521 E LEE ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/18/2007 PLUMBING - GAS PRESSURE TEST Approved
04/12/2007 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
AFTER HRS. REQ. BY MIKE LOPEZ @ 631-0312 $108.00 FEE
PAID W/CHECK 03630

TWO UNITS 3521 & 3523
SECURE STRUT CLAMPS
SEPARATE COPPER FLEX FROM VENT CONNECTOR
PROVIDE COMBUSTION AIR OPENINGS
PROVIDE LISTING FOR 1" BALL VALVES ASME B.1633
WRAP PIPE & VISE JAW MARKS BELOW GRADE
UTILITY CLEARANCE GIVEN, IF BV'S ARE NOT LISTED FOR NAT. GAS, THEY WILL HAVE TO BE CHANGES AND RETESTED.