Permit: T07PL00583

Inspection Status: Approved

Inspection History: SEWER - PRE CONSTRUCTION MTG

Date Description Inspector Results Comments
07/23/2007 SEWER - PRE CONSTRUCTION MTG Approved IVRS - Inspection :*
CITY APPROVED PLAN IS ON SITE. SECTIONS OF SEWER HAVE BEEN COVERED WITHOUT CITY APPROVAL
1. CONTRACTOR SHALL PROVIDE TRACER WIRE PER HOUSE BILL 2256 AND INSTALL PER PIMA COUNTY REQUIREMENTS
2. ALL HCS LATERALS SHALL BE EXPOSED FROM MANHOLE #20 THRU ENTIRE PRIVATE SEWER FOR INSPECTION & TRACER WIRE PROVIDED.
3. REDLINE ON SITE TO BE CITY APPROVED AT LATER DATE
4. AIR TESTING OF SEWERS, VACUUM TESTING OF MANHOLES AT LATER DATE. AUTHORIZATION TO DISCHARGE FROM PCDEQ REQUIRED BEFORE ANY SEWER FLOW.
07/19/2007 SEWER - PRE CONSTRUCTION MTG Not ready for Inspection IVRS - Inspection :*