Permit: T07PL00538

Parcel: 116210110


Addresses:

77 S GRANDE AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07PL00538

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/12/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
1. OWNER IS AWARE OF DANGERS IN USING PVC WATER PIPE IN EXPOSED AREAS.
2. OWNER TO INSTALL CPVC 90 DEG. ELLS ON T&P RELIEF DRAIN
3. PRESSURE TEST OK - OK TO BACKFILL
4. ALL OTHER CORRECTIONS MADE OK
5. UCC LEFT AT METER - BOTH UNITS
06/07/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
79 S GRANDE AV
1. PROVIDE PSI TEST MIN. 3 PSI
2. COMPLETE INSTALL OF FLUE VENT FOR WATER HEATER
3. PROVIDE 1" CLEAR AROUND FLUE VENT THRU ROOF

77 S GRANDE AV
1. PROVIDE PSI TEST MIN. 3 PSI
2. PROVIDE AGA APPROVED VALVES & FLEXES FOR
STOVE AND FURNACE
04/18/2007 PLUMBING - FINAL Not ready for Inspection 1. PROVIDE SEDIMENT TRAP FOR WATER HEATER.
2. PROVIDE APPROVED PIPING FOR T&P AND RUN TO DAYLIGHT
3. PROVIDE 1" CLEAR AROUND FLUE VENT THRU ROOF
4. EXTEND FLUE VENT FOR FURNACE 2' ABOVE COOLER
5. UNABLE TO INSPECT INSIDE UNIT NO ONE HOME
6. LIST MAY NOT BE COMPLETE