Permit: T07PL00526

Parcel: 12217297D


Addresses:

3155 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07PL00526

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/01/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
INSTALLED PER DELTA TWO REVISION
OK TO COVER
WATER TEST ONE RISER TO TEN FEET
04/23/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection 1. NOT INSTALLED PER THE REVISED APPROVED PLAN
2. PLAN STILL SHOWS THE 2" SINK DRAIN CONNECTING TO THE BLDG. DRAIN

YOU ARE STILL CONNECTED TO THE BLDG. SEWER
REMOVE SANTEE AT EXTERIOR WALL AND USE PROPER DRAINAGE FITTINGS.
04/17/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. PLAN CLEARLY SHOWS 2" WASTE CONNECTING TO EXISTING BLDG. DRAIN. YOU HAVE CONNECTED TO THE BLDG. SEWER AND RAN THE WASTE PIPING EXPOSED ON THE EXTERIOR WALL. YOU MUST PROVIDE THE LISTING FOR THE AAV TO BE INSTALLED IN AN EXPOSED EXTERIOR LOCATION
2. NOT INSTALLED PER PLAN
NO REDLINES ON SITE