Permit: T07PL00495

Parcel: 128141300


Addresses:

5150 E 21ST ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/28/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS CARD ON PIPE AT METER
03/26/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) COMPLETE LIST FROM 3/22/07 #2 & #7
03/23/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
PIPING IN ATTIC SECURED OK
COMPLETE OTHER ITEMS ON 3/22/07 SHEET
03/22/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE BONDING OF BUILDING GAS PIPING.
2. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN TO DAYLIGHT TERMINATING AT 90 DEG. DOWN 6"-24" FROM FINISHED GRADE.
3. WATER HEATER VENT PIPING TO BE APPROVED MATERIAL (SINGLE WALL IN CLOSET) WITH 3 - GALV SCREWS AT EACH JOINT. TRAVELING IN UP DIRECTION.
4. SHALL PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER & FURNACE.
5. SHALL PROVIDE COMBUSTION AIR FOR WATER HEATER CLOSET.
6. SHALL PROVIDE ACCESS (LADDER) TO ATTIC FOR INSPECTION.
7. SEAL PIPE PENETRATIONS INTO BUILDING
03/20/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ONE ON SITE UNABLE TO DO INSPECTION