Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07PL00469
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/13/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
04/26/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. VENT PIPING TO BE MADE UP CORRECTLY AND HAVE 3-GALV SCREWS AT EACH JOINT. 2. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN SHALL BE RIGID FULLSIZE APPROVED PIPING GRAVITY DRAIN TO DAYLIGHT. 3. VENT FROM WATER HEATER TO TERMINATE MINIMUM 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE. |