Permit: T07PL00426

Parcel: 127041150


Addresses:

4908 E 2ND ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/23/2007 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
03/21/2007 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
4908 --
PROVIDE LADDER TO ACCESS ATTIC
PROVIDE PLAN FOR SIZING TO FURNACE, STOVE & WH
SECURE PIPING AT FURNACE
SEDIMENT TRAPS MIN. LENGTH IS 3"
USE 3" FLASHING AT ROOF, SEAL FLASHING.
PROVIDE COMBUSTION AIR OPENING
TOOL MARK BELOW GRADE NEAR ELBOW

4910 --
USE LISTED B VENT SUPPORT ON WH VENT
TERMINATE T&P 6"-24" ABV GRADE
PROVIDE PERMIT OR PROOF OF INSPECTION FOR FURNACE
03/15/2007 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
4908 E 2ND ST
LEAKING.
NOT PER PLAN.
CORRECT WH T&P AND VENT

4910 E 2ND ST
15 PSI OK
PRIME THEN WRAP ALL TOOL MARKS BELOW GRADE
PIPE GAS VALVE INTO WH ENCLOSURE
BOND TO PANEL
FURNACE INSPECTION