Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07PL00424

Parcel: 131050780


Addresses:

5118 E 29TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/21/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
03/09/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL SECURE GAS PIPING AT DROP AT FURNACE/WATER HEATER CLOSET. THIS PIPING SHALL BE ARRANGED TO PROVIDE PULL SPACE FOR APPLIANCES.
2. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN SHALL GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL FORM, ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF SIGNED BY CITY OBTAINED AT 201 N STONE
ONSITE WITH CORRECT INSTALLATION.
3. PROVIDE BONDING OF BUILDING GAS PIPING
4. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER & FURNACE.