Permit: T07PL00399

Parcel: 130100790


Addresses:

3265 E 24TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
05/30/2007 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
05/08/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. TEST NOT HOLDING
2. INSTALL SEDIMENT TRAP DOWN FOR WATER HEATER AND INSTALL AGA APPROVED VALVES
3. HARD PIPE T&P
4. ENCLOSE WATER HEATER
03/16/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. PROVIDE APPROVED COUPLING AND TAPE & PRIMER
2. PROVIDE ELECTRICAL BONDING
3. PROVIDE A PRESSURE TEST GAUGE WITH 1/10 PSI INCREMENTATION.
4. EXTEND FLUE VENT FOR FURNACE 2' ABOVE COOLER
5. COMPLETE WORK ON WATER HEATER
WATER HEATER NOT INSTALLED
6. UNABLE TO INSPECT FURNACE
7. LIST MAY NOT BE COMPLETE
8. PROVIDE SEDIMENT TRAPS FOR WATER HEATER