Permit: T07PL00382

Parcel: 135112280

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/25/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
05/10/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ONE HOME UNABLE TO DO INSPECTION 2:20PM
04/04/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SHALL PROVIDE SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER.
2. TEMPERATURE & PRESSURE RELIEF DRAIN PIPING TO BE FULL SIZE RIDGID PIPING (NO FLEX) GRAVITY DRAIN TO DAYLIGHT TERMINATING AT 90 DEG. DOWN
6" TO 24" FROM FINISHED GRADE.