Permit: T07PL00331

Parcel: 111063700


Addresses:

2810 N FLANWILL BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/06/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
1) OBTAIN GAS CLEARANCE FROM MECHANICAL INSPECTION AFTER INSPECTIONS
03/08/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1. TEST ON PIPING IS OK
2. SINGLE WALL STOVE PIPE FROM FURNACE PENETRATING ROOF IS A CODE VIOLATION.
3. FURNACE IS RELATIVELY NEW .
4. PROVIDE PROOF OF INSPECTION FOR FURNACE OR PERMIT AND HAVE INSPECTED.
5. PROTECT WH INSTALLED OUTSIDE WITH AN ENCLOSURE
6. SUPPORT WH ON FIRM BASE
7. T&P SHALL TERMINATE WITHOUT THREADS.
03/01/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
UNABLE TO BE AT HOME 1:15 PM
(CANCELLED)