Permit: T07PL00302

Parcel: 133146610

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/05/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
03/01/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1. WAITED FOR A LADDER TO INSPECT ABOVE CEILING.
2. SUPPORT HORIZONTAL DRAIN LINE W/PIPE SUPPORT.
3. PREVIOUS INSPECTION WAS FOR AN EXPIRED PERMIT FROM 2000 THAT NEEDS TO BE FINALED.
4. PLEASE CALL FOR INSPECTION FOR OPEN ACTIVITY
FROM 2000 AND PROVIDE ANY INSPECTION HISTORY.
5. TEMP CAPS HAVE BEEN INSTALLED, NO OBVIOUS PLUMBING HAZARDS EXIST.
6. WC AND LAV MAY NOT MEET ACCESSIBILITY REQUIREMENTS CALL FOR BUILDING INSPECTION.
02/26/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SOME FIXTURES HAVE BEEN REMOVED.
2. TEMPORARILY CAP ANY OPEN SEWER PIPES.
3. AT SOUTH EASTERN SECTION OF SUITE TWO RMS W/SINK PIPING PER PLAN DATED 5/30/00; OVERHEAD PIPING NEEDS TO BE PROPERLY SUPPORTED. FIXTURES HAVE BEEN REMOVED.
4. ALL FIXTURES NEED TO BE INSTALLED OR WATER & DRAIN PIPING WOULD NEED TO BE PERM CAPPED.
5. FACILITY MANAGEMENT OR RESPONSIBLE PARTY NEEDS TO SCHEDULE AN INSPECTION AND PROVIDE ANY PREVIOUS INSP. HISTORY.
6. I BELIEVE THAT THERE IS ALSO AN OPEN WATER HEATER PERMIT. WATER HEATER ABV CEILING REQUIRES A DRAIN TO EXTERIOR.
02/15/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
T&P DRAIN & DRAIN PAN CANNOT COMBINE
PIPE T&P TO EXTERIOR SEPARATELY
FLEX NOT ALLOWED ON T&P
SUPPORT DRAIN LINES
LEAVE A CONTACT NUMBER