Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/12/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* PETITION OF APPEAL #220-07 ON SITE GAS CARD AT METER |
|
| 02/09/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. TEST SHALL HOLD WITH NO PRESSURE LOSS 2. VENTS TO BE CORRECT INSTALL WITH NOTE 34 FROM 2/7/07 FOR WATER HEATER & FURNACE. 3. SEE NOTE #6 2/7/07 & COMPLY 4. SHALL PROVIDE 125# PRESSURE RELIEF DEVICE |
|
| 02/07/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) EXTEND 1" PIPING TO ABOVE GRADE, PRIME, TAPE, TOOL MARKS, FITTINGS AND PIPE 2) SHALL PROVIDE APPROVED GAS VALVES BY ALL APPLIANCES 3) WATER HEATER TO HAVE TEMPERATURE AND PRESSURE RELIEF DRAIN APPROVED PIPING GRAVITY DRAIN TO DAYLIGHT OR CITY SIGNED PETITION OF APPEAL WITH CORRECT INSTALLATION 4) VENTS FROM APPLIANCES TO HAVE 3 GALV SCREWS AT EACH JOINT 5) PROVIDE SEDIMENT TRAPS AT WATER HEATER FURNACE 6) SHALL PROVIDE BONDING OF BLDG GAS PIPING 7) VENT FROM FURNACE TO BE 2' ABOVE COMBUSTION AIR INTAKE WHEN WITHIN 10' DBL WALL VENT PIPING |