Permit: T07PL00232

Parcel: 127080420


Addresses:

5433 E HOLMES ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/13/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
02/02/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) OK FOR GAS AFTER ? VENT
2) PROVIDE 1" OF CLEARANCE BETWEEN WOOD AND B-VENT AT WH VENT ROOF PENETRATION
3) EXTEND WH B VENT TO 3' ABOVE COOLER
4) CARD GIVEN