Permit: T07PL00222

Parcel: 126040260


Addresses:

4431 E 3RD ST #05


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07PL00222

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/16/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
02/13/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
MET W/PERSON DOING WORK
1. USE A GAUGE WITH 1/10 PSI INCREMENTATION FOR REQUIRED MIN. PRESSURE TEST.
2. REMOVE UNNEEDED/FUTURE TEE AT CEILING ABOVE PIPING DROP AT WH/FURNACE.
3. REMOVE EMT UNISTRUT CLAMP THAT IS TOO LARGE TO SECURE PIPE.
4. REMOVE EMT STAND OFF BRACKET.
5. USE PIPE CLAMPS OF THE CORRECT SIZE TO SUPPORT AND SECURE PIPING.
6. SEE PIPING FOR UNIT G & D
02/09/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTHING HAS BEEN DONE SINCE LAST INSPECTION
CONTINUED N/R OR DENIED INSPECTIONS MAY RESULT IN REINSPECTION FEES.
02/08/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GAUGE AT ZERO-CHECK FOR LEAKS
2) REMOVE TEE OVERHEAD AT PIPE DROP
3) ELECTRICAL BONDING REQUIRED
4) USE PIPE CLAMPS NOT CONDUIT CLAMPS ( 2 HOLE CLAMPS OR UNITSTRUT CLAMPS)
5) PIPE CLAMPS SHALL BE SIZED FOR 1" 1P
6) SEDIMENT TRAPS
7) CAP OR PLUG OR REMOVE OLD PIPING
8) FAILURE TO COMPLY WITH REQUIREMENTS MAY RESULT IN REINSPECTION FEES
02/01/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UNIT IS IDENTIFIED AS #E
2) LABEL PIPING AT METER AS #5 AS SHOWN ON PERMIT OR CORRECT PERMIT TO REFLECT UNIT DESIGNATION
2) GAUGE READING ZERO
3) REMOVE FUTURE TEE OR PROVIDE APPROVED DRAWING SHOWING FUTURE CONNECTION
4) SECURE PIPE DROPS. SECURE VERTICAL PIPING WITH PIPE CLAMPS-USE CORRECT SIZE PIPE SUPPORTS
5) SEDIMENT TRAPS REQUIRED AT WH AND FURNACE
6) UNION IS NOT PROPERLY ALIGNED
7) PIPING SHALL NOT BE UNDER STRAIN. USE FITTINGS TO OFF SET OVER TO WALL