Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/31/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* TEST ON EXISTING PIPING FROM METER THRU BUILDING OK |
|
| 01/26/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ADDRESS ON PERMIT SHALL MATCH ADDRESS POSTED ON STRUCTURE. 2. SHALL PROVIDE TEST GAUGE THAT IS IN WORKING ORDER. 3. VENT FROM WATER HEATER SHALL BE DOUBLE WALL THRU ROOF HAVE MINIMUM 1" CLEARANCE FROM COMBUSTIBLES BE DOUBLE WALL FROM DRAFT HOOD IN EXTERIOR LOCATION TERMINATING MINIMUM 1' ABOVE ROOF WITH APPROVED VENT CAP. TO AVOID FIRE DANGER. 4. WATER HEATER SHALL HAVE APPROVED TEMPERATURE & PRESSURE RELIEF DRAIN PIPING IN PLACE TERMINATING MINIMUM 6" TO 24" FROM FINISH GRADE IN DOWNWARD DIRECTION TO AVOID SCALDING HAZARD. 5. NOTE: IF BUILDING REQUIRES NEW GAS PIPING THERE MAY BE ADDITIONAL REQUIREMENTS TO MEET 2003 UPC REQUIREMENTS. |