Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
Permit Number - T07PL00160
Inspection Description - SITE - SEWER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/16/2007 | SITE - SEWER | Approved | ||
04/25/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* MANHOLE #1 - VACUUM TEST OK MANHOLE #2 - DENIED RETEST OK MANHOLE #3 - DENIED RETEST OK MANHOLE #4 - OK MANHOLE #5 - OK MANHOLE #6 - OK ALL MANH0LE VACUUM TEST OK |
|
03/23/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" AIR TEST FROM PUBLIC MANHOLE #1 TO PRIVATE MH#6 (3) LATERALS OK FROM MANHOLE #1 TO #2 OK W/HCS'S FROM MH#2 TO #3 OK W/HCS'S FROM MANHOLE #3 TO #4 OK FROM MANHOLE #4 TO #5 WITH HCS'S OK FROM MANHOLE #5 4" HCS LATERAL TO BUILDING OK FROM MANHOLE #6 4" HCS LATERAL TO BUILDING OK PIMA COUNTY WASTEWATER MANAGEMENT MANUAL FOR ENGINEERING STANDARDS & PROCEDURES PAGE 28 OF STANDARD SPECIFICATION SECTION. |
|
03/16/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* ALL MANHOLE BASES & STACKS OK SHALL WITNESS VACUUM TESTING AT LATER DATE |
|
03/14/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* MANHOLES STACKED AT MANHOLE #3, 4, 5 TRACER WIRE TO BE TO SURFACE OF MANHOLE. |
|
03/12/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* | |
03/09/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* FROM PUBLIC MANHOLE #1 EAST TO PRIVATE MANHOLE #2 #3, #4, #5 INCLUDING HCS WYES BEDDING, LAYING, TRACER, SHADING OK 1. SHALL AIR TEST PIPING, VACUUM TEST MANHOLES AT LATER DATE. |